Celadon Infrared Remote Control and Receiver Systems
Infrared Remote Controls Infrared Receivers Information Request Form Celadon Company Profile Contact Celadon Sales

-back to custom RS232 device list

IR to RS232 Codes Output Table for RCV-5000 Infrared Receiver

InFocus SP7200 Projector

Celadon Inc. 
RCV-5000  IR to RS-232 Output Table
Device: InFocus SP7200 Projector
Infrared Remote Control: Philips PRONTO, Niles Intellicontrol
Infrared Code Format: NEC - Device ID: 7B02
Infrared Pronto Data File(s): See "IR Code Read Me - RCV-5000.txt" for complete description
Infrared Receiver: Celadon RCV-5000 Infrared to RS-232 Receiver
RCV-5000 Data File: infocus2_r.hex
Data: 19200 Baud, 8, N, 1, ASCII Output
Standard Transmit and Receive pinout
NOTE: All ASCII Strings have Carriage Return Proceeding
Infocus SP7200 Function Pronto Button RCV-5000 Output
Aspect Ratio - Native 0 (ARZ0)
Aspect Ratio - 16:9 1 (ARZ1)
Aspect Ratio - 4:3 2 (ARZ2)
Aspect Ratio - Letterbox 3 (ARZ3)
Aspect Ratio - Natural Wide 4 (ARZ4)
Power Enable - 0 (OFF) 5 (PWR0)
Power Enable - 1 (ON) 6 (PWR1)
Source - PC1 - Analog 7 (SRC0)
Source - PC1 - Digital 8 (SRC1)
Source - Video 3 - Component HDTV 9 (SRC2)
Source - Video 3 - Component 10 (SRC3)
Source - Video 1 - S-Video 11 (SRC4)
Source - Video 2 - Composite 12 (SRC5)
Source - PC2 - Component 13 (SRC6)
Source - PC2 - VESA 14 (SRC7)
Preset - User 1 15 (PST0)
Preset - User 2 16 (PST1)
Preset - User 3 17 (PST2)
Lamp Hours - Read Only 18 (LMP0)
Celadon, Inc.
500 Tamal Plaza, Suite 520
Corte Madera, CA 94925
Sales: (415) 472-1177 x201
Main Tel: (415) 472-1177
Main Fax: (415) 472-1179
sales@qualityremotes.com

Download the Infrared (IR) Code Files for the Pronto Remotes (.ccf and .pcf)


Celadon, Inc. | 58 Paul Drive, Suite D | San Rafael, CA 94903 U.S.A. | Sales: +1 (415) 472-1177 x201 | Fax: +1 (415) 472-1179
© Celadon, Inc. 2024 All Rights Reserved